1-321-802-5889

NSN 5925-01-222-6638

Overload Switch

About this product

Single pole type body style, plastic case material, at 12 oclock nonturn device location, switch contact arrangement: single pole, double throw.

Manufacturer part number M55629/20RR for national stock number 5925012226638.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-01-222-6638.

  • MPN or Model

    M55629/20RR

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    0.3 lb
  • Body Style
    Single pole type
  • Bushing Length
    Between 0.464 inches and 0.526 inches
  • Body Length
    Between 1.969 inches and 2.031 inches
  • Body Width
    Between 0.735 inches and 0.765 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    Between 1.499 inches and 1.561 inches
  • Nonturn Device Location
    At 12 oclock
  • Nonturn Device Radius
    Between 0.641 inches and 0.671 inches
  • Nonturn Device Length
    Between 0.115 inches and 0.145 inches
  • Nonturn Device Diameter
    0.138 inches
  • Switch Contact Arrangement
    Single pole, double throw
  • Fragility Factor
    Moderately rugged
  • Mounting Surface To Terminal End Distance
    2.232 inches
  • Pole Quantity
    1
  • Arc Quenching Method
    Magnetic blowout
  • Mounting Facility Type And Quantity
    1 threaded bushing w/panel seal
  • Storage Type
    General purpose warehouse
  • Special Handling Feature
    Magnetic
  • Thready Qty Per Inch (tpi)
    32
  • Maximum Continuous Load Current Rating Per Pole
    25.0 amperes dc single location
  • Operating Voltage Type And Rating Per Pole In Volts
    50.0 dc single location
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    2000.0 dc single location
  • Circuit Protection Type
    Overcurrent single location
  • Trip Release Method
    Magnetic single location
  • Trip Release Characteristic
    Time delay single location
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    125.0 single location
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole two
  • Auxiliary Switch Function And Quantity
    1 alarm
  • Internal Trip Release Configuration
    Series trip single location
  • Thread Size
    0.500 inches
  • Switch Location And Position Designation
    Internal at pole one
  • Trip Delay Time In Seconds Per Rated Continuous Current
    0.130 at 200 pct single location and 1.500 at 200 pct single location
  • Inclosure Protection Type For Which Designed
    Fungus resistant
  • Switch Terminal Type
    Tab, solder lug
  • Switch Current Rating And Type In Amps
    10.0 ac and 2.0 dc
  • Switch Voltage Rating And Type In Volts
    250.0 ac and 50.0 dc
  • Test Data Document
    81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
  • Thread Series Designator
    Un
  • Terminal Type And Quantity
    2 tab w/screw
  • Specification Data
    81349-mil-c-55629/20 government specification
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-01-222-6638 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925012226638

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
M55629/20RR Military Specifications
MIL-C-55629/20 Military Specifications
MIL-PRF-55629/20 Military Specifications
Stock Check