Datasheet
-
Product description
Circuit Breaker NSN 5925-01-222-6642.
-
MPN or Model
M39019/02-337
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Single pole type -
Bushing Length
Between 0.332 inches and 0.380 inches -
Body Length
Between 1.531 inches and 1.562 inches -
Body Width
Between 0.594 inches and 0.625 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
Between 0.875 inches and 0.906 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
End Application
Submarine acoustic sonar systems; submarine (ssn) fire control sys; los angeles class ssn (688); mobile subscriber equipment (mse); submarine armament and fire control systems; sonar, an/bsy- (v); over the horizon back scanner (oth-b) program (an/fps-118) ; aircraft, f-16 -
Mounting Surface To Terminal End Distance
Between 1.669 inches and 1.700 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
Thd bushing w/panel seal -
Storage Type
General purpose warehouse -
Features Provided
High inrush protection -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location and 15.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location and 50.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location and 500.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.375 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 at 200 pct single location and 9.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and hermetically sealed -
Switch Terminal Type
Tab, solder lug -
Criticality Code Justification
Feat -
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc -
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc -
Frequency In Hertz
400.0 single location -
Unpackaged Unit Weight
50.0 grams -
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unef -
Terminal Type And Quantity
2 wire hook -
Specification Data
81349-mil-c-39019/2 government specification
More from these suppliers
- 5905-00-004-5816 MPN RBR53L64900BRNoninductive Wire Wound Fixed Resistor
- 5905-00-004-6037 MPN MILR39005-6Noninductive Wire Wound Fixed Resistor
- 5935-00-004-7675 MPN M83723/24R2015NElectrical Plug Connector
- 5905-00-005-2799 MPN M22-02-0024-1SBNonprecision Wire Wound Variable Resistor
- 5905-00-005-2863 MPN RBR52S42001BMNoninductive Wire Wound Fixed Resistor
- 5905-00-005-2884 MPN RNR55J2612BPFilm Fixed Resistor
- 5905-00-005-2901 MPN RNC55H2610FPFilm Fixed Resistor
- 5905-00-006-5563 MPN RLR05C562GPFilm Fixed Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-222-6642 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M39019/02-337 | Military Specifications |
MIL-PRF-39019/2 | Military Specifications |
MIL-C-39019/2 | Military Specifications |