NSN 5925-01-223-9230
Overload Switch
Multipole-single actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 2.
Manufacturer part number APGN66-9739-15 for national stock number 5925012239230.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-223-9230.
-
MPN or Model
APGN66-9739-15
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Multipole-single actuator type -
Bushing Length
Between 0.615 inches and 0.635 inches -
Body Length
Between 1.990 inches and 2.010 inches -
Body Width
Between 1.490 inches and 1.510 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.520 inches and 1.540 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.740 inches and 0.760 inches -
Fragility Factor
Moderately rugged -
End Application
5895-01-108-5631 -
Mounting Surface To Terminal End Distance
Between 2.222 inches and 2.242 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
7.0 amperes ac first location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.500 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct and 1.600 at 200 pct first location -
Inclosure Protection Type For Which Designed
Fungus resistant -
Frequency In Hertz
50.0 or 60.0 all locations -
Unpackaged Unit Weight
6.000 ounces -
Thread Series Designator
Un -
Terminal Type And Quantity
4 tab w/screw
More from these suppliers
- 5925-00-148-8241 MPN SM3-10-24DC2Circuit Breaker
- 5925-00-279-5578 MPN PX0411TSMG4-20-125VDCCircuit Breaker
- 5925-00-331-9297 MPN PAM12MG6-7-50VDCCircuit Breaker
- 5925-00-433-9082 MPN GJ3-G3-225-250-2Circuit Breaker
- 5925-00-469-5300 MPN AM33MG6-1-250VAC60C4Circuit Breaker
- 5925-00-529-0441 MPN HE1Z6-117Circuit Breaker
- 5925-00-553-2407 MPN AM13WG6-35A117VAC60C4Circuit Breaker
- 5925-00-728-7996 MPN SM333-1-5-400-2AND17-10018Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-223-9230 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APGN66-9739-15 | Sensata Technologies Maryland, Inc |
SM-A-988733-15 | Us Army Communications & |
JE2S-Z1-1 | Eaton Corp |