NSN 5925-01-225-9333
Overload Switch
Relay coil has a special electrical short for mechanical trip.
Manufacturer part number 56-002-002 for national stock number 5925012259333.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-225-9333.
-
MPN or Model
56-002-002
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.5 lb -
Body Style
Multipole-multiple actuator type -
Bushing Length
0.130 inches -
Body Length
2.000 inches -
Body Width
2.250 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.531 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.656 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.898 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Features Provided
High inrush protection -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac third location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay first location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip second location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.200 at 200 pct and 20.000 at 200 pct second location -
Inclosure Protection Type For Which Designed
General purpose -
Frequency In Hertz
50.0 or 60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 screw
More from these suppliers
- 5925-00-270-5899 MPN PAM1510-50-250-60Circuit Breaker
- 5925-00-284-2714 MPN 2263S3Circuit Breaker
- 5925-00-400-4937 MPN AM33MG6-40-250-4-60Circuit Breaker
- 5925-00-413-0344 MPN 2XAM1516HKMG-54-208-2-400Circuit Breaker
- 5925-00-617-9571 MPN AM13MG6-0-5-125-4-60Circuit Breaker
- 5925-00-912-5326 MPN AM333MG6-10-250-60-4Circuit Breaker
- 5925-01-007-2049 MPN 009-18054Circuit Breaker Handle
- 5925-01-013-9650 MPN CD313D760-240-3Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-225-9333 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
56-002-002 | Tdk-lambda Americas Inc. |
UPGH667-2995-1 | Sensata Technologies Maryland, Inc |
JA3-Z-301-2 | Eaton Corp |