NSN 5925-01-227-2354

Overload Switch

About this product

Rectangular dimensional envelope body style, metal case material, moderately rugged fragility factor, pole quantity: 2.

Manufacturer part number ACB2601R TRP U COIL RTG 2600A for national stock number 5925012272354.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-01-227-2354.

  • MPN or Model

    ACB2601R TRP U COIL RTG 2600A

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Body Style
    Rectangular dimensional envelope
  • Overall Length
    29.125 inches
  • Overall Height
    24.000 inches
  • Overall Width
    25.250 inches
  • Case Material
    Metal
  • Fragility Factor
    Moderately rugged
  • Pole Quantity
    2
  • Arc Quenching Method
    Air
  • Storage Type
    General purpose warehouse
  • Maximum Continuous Load Current Rating Per Pole
    2600.0 amperes dc all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    75000.0 dc all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Thermal all locations
  • Trip Release Characteristic
    Instantaneous all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    150.0 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Internal Trip Release Configuration
    Series trip all locations
  • Inclosure Protection Type For Which Designed
    Dustproof
  • Trip Release Ambient Tempurature Rating
    40.0 degrees celsius all locations
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-01-227-2354 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925012272354

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
ACB2601R TRP U COIL RTG 2600A Spd Electrical Systems, Inc
ACB2601R TRP U COIL RTG 2600A Spd Electrical Systems, Inc
ACB2601R TRP U COIL RTG 2600A Spd Electrical Systems, Inc
ACB2601R TRP U COIL RTG 2600A Spd Electrical Systems, Inc
ACB2601R TRP U COIL RTG 2600A Spd Electrical Systems, Inc
ACB2601R TRP U COIL RTG 2600A Spd Electrical Systems, Inc
ACB2601R TRP U COIL RTG 2600A Spd Electrical Systems, Inc
ACB2601R TRP U COIL RTG 2600A Spd Electrical Systems, Inc
ACB2601R TRP U COIL RTG 2600A Spd Electrical Systems, Inc
ACB2601R TRP U COIL RTG 2600A Spd Electrical Systems, Inc
ACB2601R TRP U COIL RTG 2600A Spd Electrical Systems, Inc
ACB2601R TRP U COIL RTG 2600A Spd Electrical Systems, Inc
ACB2601R TRP U COIL RTG 2600A Spd Electrical Systems, Inc
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.