NSN 5925-01-228-3031
Overload Switch
Operating voltage for voltage sensing coil,107.0 volt full wave rectified dc.
Manufacturer part number C10010-6 for national stock number 5925012283031.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-228-3031.
-
MPN or Model
C10010-6
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.5 lb -
Body Style
Multipole-multiple actuator type -
Body Length
Between 2.490 inches and 2.510 inches -
Body Width
Between 1.490 inches and 1.510 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.928 inches and 1.948 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.740 inches and 0.760 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.052 inches and 2.072 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.740 inches and 0.760 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.130 inches and 0.150 inches -
Mounting Surface To Terminal End Distance
Between 2.461 inches and 2.481 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 clip and 4 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1200.0 ac all locations -
Circuit Protection Type
Undervoltage second location -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay first location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Relay trip second location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 at 200 pct and 80.000 at 200 pct first location -
Inclosure Protection Type For Which Designed
General purpose -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5925-00-054-0402 MPN SM333HHK7-5-240VAC400C1Circuit Breaker
- 5925-00-164-0992 MPN AM1-A3-A-07R5-02ECircuit Breaker
- 5925-00-182-7452 MPN AM12MG6-50-30DC5Circuit Breaker
- 5925-00-449-0047 MPN AM12-25M6Circuit Breaker
- 5925-00-549-6803 MPN AM1615G3-70-28DCCircuit Breaker
- 5925-00-721-3206 MPN SM4-1-5-240VAC45-440C1Circuit Breaker
- 5925-00-725-8811 MPN AM12MG3-5-208VAC400-16Circuit Breaker
- 5925-00-820-4170 MPN 1163SMG4-20ACircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-228-3031 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
C10010-6 | Lockheed Martin Corporation |
AM2-Z442-1 | Eaton Corp |