NSN 5925-01-230-0409
Overload Switch
Multipole-multiple actuator type body style, 0.164 inches mounting slot width, plastic case material, switch contact arrangement: single pole, double throw.
Manufacturer part number 77C721912P001 for national stock number 5925012300409.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-230-0409.
-
MPN or Model
77C721912P001
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
2.8 lb -
Body Style
Multipole-multiple actuator type -
Mounting Slot Width
0.164 inches -
Body Length
5.844 inches -
Body Width
3.093 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.546 inches -
Center To Center Distance Between Terminals Parallel To Width
1.032 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.032 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
2.609 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole and 6 slot -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.120 at 200 pct and 0.180 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Moisture resistant and shock resistant and vibration resistant -
Switch Terminal Type
Turret -
Switch Current Rating And Type In Amps
0.1 dc -
Switch Voltage Rating And Type In Volts
6.0 dc -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5935-00-189-4908 MPN 7418414P8Electrical Connector Cover
- 5950-00-443-1490 MPN 77C708618-1Power Transformer
- 5940-00-504-3251 MPN 7129230-5Grounding Metallic Shielded Cable Ferrule
- 5930-00-519-6354 MPN 7703852P15Lever Switch
- 5950-00-617-4783 MPN 7609812P011Radio Frequency Coil
- 5950-00-646-2856 MPN B7485527Reactor
- 5950-00-648-6620 MPN 7485535P001Audio Frequency Transformer
- 5945-00-722-3198 MPN 7703204P4REVBElectromagnetic Relay
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-230-0409 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
77C721912P001 | Lockheed Martin Corporation |
CD3-Z390-2 | Eaton Corp |