NSN 5925-01-231-1897
Overload Switch
Multipole-single actuator type body style, plastic case material, at 3 oclock and at 9 oclock and at 12 oclock nonturn device location, switch contact arrangement: single pole, double throw.
Manufacturer part number M55629/22RMUMUM for national stock number 5925012311897.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-231-1897.
-
MPN or Model
M55629/22RMUMUM
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.6 lb -
Body Style
Multipole-single actuator type -
Bushing Length
Between 0.464 inches and 0.526 inches -
Body Length
Between 1.969 inches and 2.031 inches -
Body Width
2.265 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.499 inches and 1.561 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.735 inches and 0.765 inches -
Nonturn Device Location
At 3 oclock and at 9 oclock and at 12 oclock -
Nonturn Device Radius
Between 0.641 inches and 0.671 inches -
Nonturn Device Length
Between 0.115 inches and 0.145 inches -
Nonturn Device Diameter
0.138 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
2.232 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac third location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.500 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 at 200 pct all locations and 20.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
10.0 ac and 2.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Frequency In Hertz
60.0 all locations -
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Un -
Terminal Type And Quantity
6 tab w/screw -
Specification Data
81349-mil-c-55629/22 government specification
More from these suppliers
- 5905-00-005-2698 MPN RNC55K8661FSFilm Fixed Resistor
- 5905-00-005-2705 MPN RNR70C4321FMFilm Fixed Resistor
- 5905-00-005-2706 MPN RNR70C4531FMFilm Fixed Resistor
- 5935-00-005-2830 MPN M83723/74R1005NElectrical Receptacle Connector
- 5905-00-006-5603 MPN RNR60C6041FRFilm Fixed Resistor
- 5905-00-009-3117 MPN RB17CE83501BNoninductive Wire Wound Fixed Resistor
- 5935-00-009-4512 MPN MIL-C-38999Electrical Plug Connector
- 5905-00-018-9258 MPN MIL-R-11804/2Film Fixed Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-231-1897 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M55629/22RMUMUM | Military Specifications |
MIL-PRF-55629/22 | Military Specifications |
MIL-C-55629/22 | Military Specifications |
Stock Check
- NE: 10
- NS: 1