NSN 5925-01-236-1017
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number UPL-11-1R0-9851-1 for national stock number 5925012361017.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-236-1017.
-
MPN or Model
UPL-11-1R0-9851-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.5 lb -
Body Style
Multipole-multiple actuator type -
Body Length
Between 2.480 inches and 2.500 inches -
Body Width
1.515 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.925 inches and 1.955 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.735 inches and 0.765 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.735 inches and 0.765 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.135 inches and 0.165 inches -
Mounting Surface To Terminal End Distance
2.490 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac first location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location -
Circuit Protection Type
Overvoltage second location -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay first location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
200.0 first location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct first location and 15.000 at 200 pct first location -
Inclosure Protection Type For Which Designed
Moisture resistant and salt spray proof and shock resistant and vibration resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
10.0 ac and 10.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 65.0 dc -
Frequency In Hertz
50.0 first location or 60.0 first location -
Unpackaged Unit Weight
7.400 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud
More from these suppliers
- 5945-00-553-9611 MPN A300Electronic Chopper
- 5925-00-192-3217 MPN APL1-124-4Circuit Breaker
- 5925-00-979-9075 MPN AP12-35-99Circuit Breaker
- 5925-01-069-2994 MPN APL112-3510-2Circuit Breaker
- 5925-01-096-4683 MPN APL1-9AMP250VAC60C62Circuit Breaker
- 5925-01-141-6688 MPN AP-112-1R-62F-252Circuit Breaker
- 5925-01-145-5328 MPN APL1113-ER6864Circuit Breaker
- 5925-01-157-0546 MPN APL-11-1-50-153-MACircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-236-1017 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UPL-11-1R0-9851-1 | Sensata Technologies Maryland, Inc |
0N333873-4 | National Security Agency |