Overload Switch

About this product

Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.

Manufacturer part number 6363-1-2 for national stock number 5925012388562.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-01-238-8562.

  • MPN or Model

    6363-1-2

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    0.1 lb
  • Body Style
    Single pole type
  • Body Length
    2.203 inches
  • Body Width
    0.765 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    1.437 inches
  • Unthreaded Mounting Hole Diameter
    0.164 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    1.812 inches
  • Fragility Factor
    Moderately rugged
  • Mounting Surface To Terminal End Distance
    1.405 inches
  • Pole Quantity
    1
  • Mounting Facility Type And Quantity
    2 unthreaded hole
  • Storage Type
    General purpose warehouse
  • Maximum Continuous Load Current Rating Per Pole
    2.0 amperes ac single location and 2.0 amperes dc single location
  • Operating Voltage Type And Rating Per Pole In Volts
    115.0 ac single location and 30.0 dc single location
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    600.0 ac single location and 900.0 dc single location
  • Circuit Protection Type
    Overcurrent single location
  • Trip Release Method
    Thermal single location
  • Trip Release Characteristic
    Time delay single location
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    125.0 single location
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole one
  • Internal Trip Release Configuration
    Series trip single location
  • Trip Delay Time In Seconds Per Rated Continuous Current
    15.000 at 200 pct single location and 30.000 at 200 pct single location
  • Inclosure Protection Type For Which Designed
    Dustproof
  • Trip Release Ambient Tempurature Rating
    25.0 degrees fahrenheit single location
  • Frequency In Hertz
    60.0 single location
  • Unpackaged Unit Weight
    1.800 ounces
  • Terminal Type And Quantity
    2 tab w/screw
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-01-238-8562 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925012388562

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
6363-1-2 Sensata Technologies, Inc
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.