NSN 5925-01-241-5091
Overload Switch
Plastic case material, at 12 oclock nonturn device location, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number 856591-7 for national stock number 5925012415091.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-241-5091.
-
MPN or Model
856591-7
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
2 lb -
Body Length
2.000 inches -
Body Width
2.265 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.515 inches and 1.545 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.735 inches and 0.765 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches -
Nonturn Device Location
At 12 oclock -
Nonturn Device Radius
0.656 inches -
Nonturn Device Length
0.130 inches -
Nonturn Device Diameter
Between 0.151 inches and 0.161 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.735 inches and 0.765 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.130 inches -
Mounting Surface To Terminal End Distance
2.032 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.500 inches -
Switch Location And Position Designation
Internal at pole three -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 20.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Corrosion resistant and moisture resistant and shockproof and vibrationproof -
Switch Terminal Type
Pin -
Switch Current Rating And Type In Amps
10.0 ac and 3.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Frequency In Hertz
60.0 all locations -
Unpackaged Unit Weight
9.000 ounces -
Thread Series Designator
Un -
Terminal Type And Quantity
6 screw
More from these suppliers
- 5950-00-019-3119 MPN 292-11109G1Power Transformer
- 5930-00-028-0065 MPN 1797-1032G1Micro Actuator Asy
- 5945-00-233-5659 MPN 746-797Electromagnetic Relay
- 5935-00-405-4578 MPN 567024-2Tip Jack
- 5935-00-445-1731 MPN 146508-306Electrical Plug Connector
- 5940-00-488-8816 MPN 143890-1Feedthru Terminal
- 5950-00-645-1199 MPN DL292-1239G1SUB1Reactor
- 5950-00-647-6619 MPN 292-1649GReactor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-241-5091 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
856591-7 | Raytheon Company |
856591-7 | Raytheon Company |
APGN-666-1REC2-2879-7 | Sensata Technologies Maryland, Inc |
856591-7 | Raytheon Company |