NSN 5925-01-242-3527
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 4.
Manufacturer part number AM-342 for national stock number 5925012423527.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-242-3527.
-
MPN or Model
AM-342
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Thread Pitch Diameters
+0.1177/+0.1214 inches -
Body Style
Multipole-multiple actuator type -
Body Length
2.490 inches -
Body Width
3.015 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.940 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.150 inches -
Mounting Surface To Terminal End Distance
2.812 inches -
Pole Quantity
4 -
Arc Quenching Method
Air -
Mounting Facility Type And Quantity
8 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac second location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac second location -
Circuit Protection Type
Undervoltage fourth location -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay first location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, three, and four linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct third location and 22.000 at 200 pct third location -
Inclosure Protection Type For Which Designed
Dustproof -
Frequency In Hertz
60.0 third location -
Thread Series Designator
Unc -
Terminal Type And Quantity
8 threaded stud
More from these suppliers
- 5945-00-925-9040 MPN 176-45Electronic Chopper
- 5925-00-232-3048 MPN AP112-1623-1Circuit Breaker
- 5925-01-034-5225 MPN AP-12-638-3Circuit Breaker
- 5925-01-048-7480 MPN 203-1-1-42-252-1-1Circuit Breaker
- 5925-01-090-3090 MPN UPL-11-1-52-302Circuit Breaker
- 5925-01-120-8756 MPN M39019/03-240Circuit Breaker
- 5925-01-157-9950 MPN UPG-7332-3Circuit Breaker
- 5925-01-169-6401 MPN 203-2-1-50-101-4-1-2Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-242-3527 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM-342 | Sensata Technologies Maryland, Inc |
APL1119-6594-1 | Sensata Technologies Maryland, Inc |
Stock Check