NSN 5925-01-247-3773
Overload Switch
For use in switchboard onboard a-class 270' u.S. Coast guard vessels.
Manufacturer part number 185L712R-136 for national stock number 5925012473773.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-247-3773.
-
MPN or Model
185L712R-136
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Pole Quantity
3 -
Cubic Measure
1.000 cubic feet -
Maximum Continuous Load Current Rating Per Pole
1600.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1600.0 ac all locations -
Circuit Protection Type
Undervoltage second location -
Trip Release Method
Magnetic all locations -
Auxiliary Trip Coil Voltage Type And Rating In Volts
120.0 ac all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Electric -
Main Contact Tripping Mechanism Type
Trip free -
Internal Trip Release Configuration
Series trip w/auxiliary load terminal and remote trip feature all locations -
Trip Release Duty Cycle
Intermittent all locations -
Frequency In Hertz
60.0 all locations -
Unpackaged Unit Weight
300.000 pounds
More from these suppliers
- 5950-00-019-6464 MPN 15D2104Electrical Coil
- 5950-00-205-9910 MPN 467A715AAP1Power Transformer
- 5905-00-225-9029 MPN 288A884EYP6Wire Wound Fixed Resistor
- 5905-00-578-9220 MPN 232B951P9Inductive Wire Wound Fixed Resistor
- 5905-00-811-4710 MPN 232B949P18Adjustable Resistor
- 5940-01-169-2439 MPN 8788918P1Terminal Board
- 5905-01-010-1043 MPN 418A740-1Film Fixed Resistor
- 5950-01-391-5631 MPN 139C5970G38Current Transformer
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-247-3773 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
185L712R-136 | General Electric Co |