NSN 5925-01-247-5315
Overload Switch
Multipole-single actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 2.
Manufacturer part number TED124010WL for national stock number 5925012475315.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-247-5315.
-
MPN or Model
TED124010WL
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
6.310 inches -
Body Width
2.750 inches -
Body Height
3.380 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
5.250 inches -
Center To Center Distance Between Terminals Parallel To Width
1.375 inches -
Unthreaded Mounting Hole Diameter
0.188 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.880 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.572 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.125 inches -
Pole Quantity
2 -
Arc Quenching Method
Air -
Mounting Facility Type And Quantity
4 unthreaded hole -
Storage Type
General purpose warehouse -
Cubic Measure
58.651 cubic inches -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations and 10.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations and 250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
14000.0 ac all locations and 10000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip all locations -
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 at 200 pct all locations and 150.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus proof -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
4 compression
More from these suppliers
- 5945-00-189-9951 MPN 152C683Electrical Solenoid
- 5930-00-620-7194 MPN CR2940UA202EPush Switch
- 5930-01-191-3279 MPN CR104MN53223Push Switch
- 5950-01-256-0101 MPN 15D1G166Electrical Coil
- 5930-01-224-7410 MPN CR103DB411BPush Switch
- 6110-01-157-8253 MPN CR306D20200ADAJAMotor Starter
- 6105-01-206-4972 MPN CR101X6Motor Base
- 5930-00-357-0641 MPN TC3065Knife Switch
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-247-5315 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
TED124010WL | General Electric Co |
TED124010WL | General Electric Co |
Stock Check
![](/public/images/partscage_shelf3.png)