NSN 5925-01-249-4749
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number 219-3-1-62F-7-8-10 for national stock number 5925012494749.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-249-4749.
-
MPN or Model
219-3-1-62F-7-8-10
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
5.125 inches -
Body Width
3.108 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.550 inches -
Center To Center Distance Between Terminals Parallel To Width
1.026 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.026 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.700 inches -
Mounting Surface To Terminal End Distance
3.550 inches -
Pole Quantity
3 -
Arc Quenching Method
Air -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 10.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Dustproof -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5945-00-071-6610 MPN 30AElectronic Chopper
- 5925-00-421-2802 MPN 620A102-18Circuit Breaker
- 5925-01-157-9949 MPN UPG7-7332-1Circuit Breaker
- 5925-01-206-4329 MPN UPG-1-1REC2-62F-602-90Circuit Breaker
- 5925-01-225-0534 MPN 203-2-9221-1Circuit Breaker
- 5925-01-300-1522 MPN 209-3-21453-1Circuit Breaker
- 5925-01-423-2425 MPN PP11-61-1.00A-XXVCircuit Breaker
- 5925-01-474-5830 MPN 219-3-1-65-8-8-30-HCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-249-4749 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
219-3-1-62F-7-8-10 | Sensata Technologies Maryland, Inc |