NSN 5925-01-249-9062
Overload Switch
Includes flux transfer shunt trip,rated 32 vdc,120 vac,60 hz.
Manufacturer part number 150-1234 for national stock number 5925012499062.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-249-9062.
-
MPN or Model
150-1234
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
37 lb -
Body Length
16.000 inches -
Body Width
8.250 inches -
Body Height
4.062 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
11.500 inches -
Center To Center Distance Between Terminals Parallel To Width
2.750 inches -
Unthreaded Mounting Hole Diameter
0.344 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
14.375 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.750 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.938 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 unthreaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Features Provided
Adjustable trip release and interchangeable trip release -
Maximum Continuous Load Current Rating Per Pole
800.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
22000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Adjustable Trip Setting Current Range Per Pole In Amps
+4000.0/+8000.0 ac all locations -
Internal Trip Release Configuration
Series trip all locations -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 45.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Corrosion resistant and fungus resistant and shock resistant and vibration resistant -
Frequency In Hertz
63.0 all locations -
Precious Material And Location
Contacts silver -
Precious Material
Silver -
Terminal Type And Quantity
6 compression
More from these suppliers
- 5945-00-465-2292 MPN 343-5361Electromagnetic Relay
- 6110-01-326-5329 MPN CR2810-B11AC1A3Magnetic Contactor
- 5930-00-549-0102 MPN S1368078Rotary Switch
- 5925-00-270-5999 MPN 1605-427Circuit Breaker Tripper
- 5925-01-437-5796 MPN 588C734G01Circuit Breaker
- 5925-01-441-9624 MPN 452D834Circuit Breaker
- 6110-01-297-3922 MPN A200M4CACDMotor Starter
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-249-9062 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
150-1234 | Continental Electronics Corporation |
MC3800F | Eaton Corp |
MDL3800F | Eaton Corporation |
150-1234 | Eaton Corporation |
MC3800F | Eaton Corporation |