NSN 5925-01-250-7965
Overload Switch
1 poles, 15.0 amperes ac single location maximum continuous load current rating per pole, 250.0 ac single location operating voltage type and rating per pole in volts, maximum interrupting capacity current type and rating per pole in amps: 1000.0 ac single location.
Manufacturer part number 203-2-2-42-153-4-1-3 for national stock number 5925012507965.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-250-7965.
-
MPN or Model
203-2-2-42-153-4-1-3
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Length
2.000 inches -
Body Width
0.920 inches -
Center To Center Distance Between Terminals Parallel To Length
1.250 inches -
Mounting Surface To Terminal End Distance
2.020 inches -
Pole Quantity
1 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Internal Trip Release Configuration
Series trip single location -
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 at 125 pct single location and 60.000 at 125 pct single location -
Frequency In Hertz
400.0 single location
More from these suppliers
- 5930-01-155-2797 MPN B11-2-7.50A-01-31A-VPump Switch
- 5925-00-168-1459 MPN APL11-23-2Circuit Breaker
- 5925-00-306-2823 MPN APL-1-1-61-202-MCircuit Breaker
- 5925-01-027-8133 MPN AP112-R-252-8Circuit Breaker
- 5925-01-064-7820 MPN UPG1-2041-1Circuit Breaker
- 5925-01-093-0734 MPN 299-3-1-42F-4-9-60Circuit Breaker
- 5925-01-145-5328 MPN APL1113-ER6864Circuit Breaker
- 5925-01-234-4761 MPN APL-1-1-52-103-MACircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-250-7965 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
203-2-2-42-153-4-1-3 | Sensata Technologies Maryland, Inc |