NSN 5925-01-257-5846
Overload Switch
Plastic case material, 3 poles, 350.0 amperes ac all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 600.0 ac all locations.
Manufacturer part number LA3350PR for national stock number 5925012575846.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-257-5846.
-
MPN or Model
LA3350PR
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
33.9 lb -
Overall Length
15.500 inches -
Overall Height
4.000 inches -
Overall Width
8.250 inches -
Case Material
Plastic -
Pole Quantity
3 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
350.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
22000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip all locations -
Frequency In Hertz
60.0 all locations
More from these suppliers
- 5945-00-445-1752 MPN 372D621G16N0NREVERSIThermal Relay
- 5930-00-884-6420 MPN 0T2S6Rotary Switch
- 5945-00-896-8899 MPN 274A789G01Electromagnetic Relay
- 5930-01-359-8947 MPN E34EB2AND01250T51Push Switch
- 5925-00-103-3883 MPN S459D985G22Circuit Breaker Tripper
- 5925-00-230-7779 MPN EA3060Circuit Breaker
- 5925-00-262-5723 MPN QC2050Circuit Breaker
- 5925-00-972-9846 MPN 457D446G23Circuit Breaker Tripper
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-257-5846 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
LA3350PR | Eaton Corporation |