NSN 5925-01-259-3598
Overload Switch
Marked 2 amps for training only.
Manufacturer part number 44-200-P10-SI-043.800-2 for national stock number 5925012593598.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-259-3598.
-
MPN or Model
44-200-P10-SI-043.800-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Bushing Length
6.5 millimeters -
Body Length
19.8 millimeters -
Body Width
15.8 millimeters -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
14.0 millimeters -
Switch Contact Arrangement
Single pole, double throw -
Mounting Surface To Terminal End Distance
43.5 millimeters -
Pole Quantity
1 -
Mounting Facility Type And Quantity
1 threaded bushing -
Thready Qty Per Inch (tpi)
27 -
Maximum Continuous Load Current Rating Per Pole
100.0 milliamperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
100.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.375 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
11.000 at 200 pct single location and 60.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
General purpose -
Trip Release Ambient Tempurature Rating
73.0 degrees fahrenheit single location -
Switch Terminal Type
Quick disconnect, male -
Criticality Code Justification
Feat -
Switch Current Rating And Type In Amps
3.0 dc -
Switch Voltage Rating And Type In Volts
28.0 dc -
Thread Series Designator
Uns -
Terminal Type And Quantity
2 quick disconnect, male
More from these suppliers
- 5925-01-085-5527 MPN 43-400-402.031Circuit Breaker
- 5925-01-605-3317 MPN 447-S-H-FN-SI-18008-175ACircuit Breaker
- 5935-00-928-7847 MPN 123019-3Electrical Plug Connector
- 5985-01-487-6443 MPN A270840-1Antenna Assembly
- 5985-01-487-6443 MPN A270840-1Antenna Assembly
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-259-3598 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
44-200-P10-SI-043.800-2 | Oakland Industries Ltd |
216556-2 | Cubic Defense Applications, Inc. |