NSN 5925-01-262-0117
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number 1802786-1 for national stock number 5925012620117.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-262-0117.
-
MPN or Model
1802786-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Single pole type -
Bushing Length
0.359 inches -
Body Length
0.750 inches -
Body Width
0.562 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
0.593 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.420 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac single location and 500.0 milliamperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 32.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac single location and 1000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.438 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct single location and 35.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Humidity resistant and vibration resistant -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Frequency In Hertz
400.0 single location -
Thread Series Designator
Uns -
Terminal Type And Quantity
2 tab w/screw
More from these suppliers
- 5985-00-099-3879 MPN 606610Waveguide Assembly
- 5940-00-113-9827 MPN 7900810-54Lug Terminal
- 5905-00-273-9698 MPN 040121470Film Fixed Resistor
- 5930-00-548-9316 MPN 15A6020-1Sensitive Switch
- 5930-00-909-9303 MPN 15A6145-28Rotary Switch
- 5905-00-958-3551 MPN RW32V330Inductive Wire Wound Fixed Resistor
- 5950-01-431-8868 MPN 260.27299Radio Frequency Transformer
- 5950-01-527-3600 MPN 4800634Power Transformer
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-262-0117 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
1802786-1 | Northrop Grumman Systems Corporation |
7277-2 1/2 | Sensata Technologies, Inc |
Stock Check
![](/public/images/partscage_shelf3.png)