NSN 5925-01-262-2893
Overload Switch
Plastic case material, moderately rugged fragility factor, 4 poles, arc quenching method: magnetic blowout.
Manufacturer part number AM4-A3A3A3A6-PL 1,2,3,20A-3PL41- for national stock number 5925012622893.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-262-2893.
-
MPN or Model
AM4-A3A3A3A6-PL 1,2,3,20A-3PL41-
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1 lb -
Body Length
Between 2.468 inches and 2.532 inches -
Body Width
Between 2.968 inches and 3.032 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.906 inches and 1.970 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.722 inches and 0.782 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.030 inches and 2.094 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.722 inches and 0.782 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.108 inches and 0.172 inches -
Mounting Surface To Terminal End Distance
Between 2.688 inches and 2.752 inches -
Pole Quantity
4 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
8 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Fragile -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay first location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, three, and four linked -
Internal Trip Release Configuration
Series trip third location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct third location and 1.500 at 200 pct third location -
Inclosure Protection Type For Which Designed
Fungus resistant and humidity resistant and moisture resistant and shock resistant and vibration resistant -
Frequency In Hertz
60.0 all locations -
Unpackaged Unit Weight
12.500 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
8 threaded stud
More from these suppliers
- 5905-01-396-9000 MPN 47A528510P5110FFilm Fixed Resistor
- 5925-01-308-7858 MPN 47A530118P15Circuit Breaker
- 5305-01-259-3546 MPN R2359P4Socket Head Cap Screw
- 5925-00-024-0434 MPN JA-1-C3-20Circuit Breaker
- 5925-00-409-3621 MPN AM2-A3A20-2Circuit Breaker
- 5925-00-433-8594 MPN AM12-10-250-400-14Circuit Breaker
- 5925-00-655-3893 MPN 53-161MG3-5-416AC-1-400HZCircuit Breaker
- 5925-00-755-5081 MPN 64-964BMG4-4AMPCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-262-2893 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM4-A3A3A3A6-PL 1,2,3,20A-3PL41- | Eaton Corp |
AM4-Z200-1 | Eaton Corp |
AM1-200-1 | Eaton Corp |
AM4-A3A3A3A6-20-3-RELAY 12VAC-P | Eaton Corp |
47A521719P19 | Lockheed Martin Corporation |