NSN 5925-01-263-9591
Overload Switch
Plastic case material, moderately rugged fragility factor, 1 poles, arc quenching method: magnetic blowout.
Manufacturer part number SM-A-838516-4 for national stock number 5925012639591.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-263-9591.
-
MPN or Model
SM-A-838516-4
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Length
Between 2.480 inches and 2.520 inches -
Body Width
Between 0.740 inches and 0.760 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.660 inches and 1.960 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.052 inches and 2.072 inches -
Fragility Factor
Moderately rugged -
End Application
5805-10-241-9710 -
Boss Height
Between 0.130 inches and 0.150 inches -
Mounting Surface To Terminal End Distance
Between 2.539 inches and 2.683 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Features Provided
High inrush protection -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct single location and 20.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
60.0 single location -
Unpackaged Unit Weight
0.188 pounds -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5925-00-056-4635 MPN 64-133-3-MG4Circuit Breaker
- 5925-00-192-3217 MPN AM1-A3-A-20-3Circuit Breaker
- 5925-00-323-9920 MPN JA-2-C3-15Circuit Breaker
- 5925-00-755-5557 MPN AM1516MG3-100A32VDC2Circuit Breaker
- 5925-00-827-4937 MPN 2XAM1516-100-250VAC60C1Circuit Breaker
- 5925-00-848-7917 MPN 74-648-2-5-208VAC320-522C54Circuit Breaker
- 5925-00-991-8722 MPN 8983140-132Circuit Breaker
- 5925-01-076-4458 MPN HE1-Z15-2Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-263-9591 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
SM-A-838516-4 | Us Army Communications & |
AM1-Z191-2 | Eaton Corp |