NSN 5925-01-275-1952
Overload Switch
Moderately rugged fragility factor, 3 poles, air arc quenching method, storage type: general purpose warehouse.
Manufacturer part number KD3400 for national stock number 5925012751952.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-275-1952.
-
MPN or Model
KD3400
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
6 lb -
Fragility Factor
Moderately rugged -
Pole Quantity
3 -
Arc Quenching Method
Air -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
400.0 amperes ac all locations and 400.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations and 250.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius all locations -
Frequency In Hertz
50.0 all locations or 60.0 all locations
More from these suppliers
- 5945-00-884-1319 MPN 373B331G08Contactor Kit
- 5950-01-237-7183 MPN 597A750G05Current Transformer
- 5930-01-529-6866 MPN 00782113560205Push Switch
- 5950-01-167-8861 MPN 505C633Opn Coil
- 5925-00-211-1900 MPN 6638C90G16Circuit Breaker
- 5925-00-867-7328 MPN 4580510G11Circuit Breaker
- 5925-00-916-6773 MPN JA3150Circuit Breaker
- 5925-00-932-9250 MPN 504C336G24Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-275-1952 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
KD3400 | Eaton Corporation |
KD3400 | Wesco Distribution Inc |