NSN 5925-01-275-2954
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number 7489A63H05 for national stock number 5925012752954.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-275-2954.
-
MPN or Model
7489A63H05
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1 lb -
Thread Pitch Diameters
+0.1177/+0.1214 inches -
Body Style
Multipole-multiple actuator type -
Body Length
2.000 inches -
Body Width
3.015 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.130 inches -
Mounting Surface To Terminal End Distance
2.032 inches -
Pole Quantity
4 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
8 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac fourth location and 15.0 amperes dc fourth location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac third location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac third location -
Circuit Protection Type
Undervoltage fourth location -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, three, and four linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip third location -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct all locations and 1.900 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Moisture resistant and shock resistant and vibration resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
5.0 ac and 3.0 dc -
Switch Voltage Rating And Type In Volts
240.0 ac and 50.0 dc -
Frequency In Hertz
400.0 all locations -
Unpackaged Unit Weight
8.000 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
8 threaded stud
More from these suppliers
- 5985-00-450-0909 MPN 990C089H01Directional Coupler
- 4920-01-092-8947 MPN 6596A38G01Electrical-electronic Equipment Test Station
- 4920-01-423-0925 MPN AD420148G01Aircraft Components Test Set Subassembly
- 4920-01-243-0347 MPN 2D06518G01Aircraft Maintenance Fixture
- 5930-01-026-0343 MPN 988C093G01Push Switch
- 5930-01-123-9989 MPN 90C99015G02Sensitive Switch
- 5945-00-688-2808 MPN 373Electronic Chopper
- 5925-00-597-1267 MPN APL111R-535-240Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-275-2954 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
7489A63H05 | Northrop Grumman Systems Corporation |
APGH9666-1REC4-21863-5 | Sensata Technologies Maryland, Inc |