NSN 5925-01-282-0505
Overload Switch
Multipole-single actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number LA36400-1021 for national stock number 5925012820505.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-282-0505.
-
MPN or Model
LA36400-1021
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
12.510 inches -
Body Width
6.000 inches -
Body Height
3.910 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
5.990 inches -
Center To Center Distance Between Terminals Parallel To Width
2.000 inches -
Unthreaded Mounting Hole Diameter
0.216 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
9.250 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.000 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.150 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 unthreaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Maximum Continuous Load Current Rating Per Pole
400.0 amperes ac all locations and 400.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations and 250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
42000.0 ac all locations and 35000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Inclosure Protection Type For Which Designed
General purpose -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
6 compression
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-282-0505 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
LA36400-1021 | Square D Co |