NSN 5925-01-283-2930
Overload Switch
Single pole type body style, plastic case material, 1 poles, thready qty per inch (tpi): 32.
Manufacturer part number T11-2-3.00A-02-20A for national stock number 5925012832930.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-283-2930.
-
MPN or Model
T11-2-3.00A-02-20A
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Single pole type -
Bushing Length
0.468 inches -
Body Length
1.375 inches -
Body Width
0.680 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.125 inches -
Mounting Surface To Terminal End Distance
1.555 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
1 threaded stud -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 50.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 1000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.500 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 at 135 pct single location and 70.000 at 135 pct single location and 2.000 at 150 pct single location and 40.000 at 150 pct single location and 1.000 at 200 pct single location and 15.000 at 200 pct single location and 0.100 at 400 pct single location and 4.000 at 400 pct single location and 0.008 at 600 pct single location and 2.000 at 600 pct single location and 0.006 at 800 pct single location and 0.800 at 800 pct single location -
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant -
Frequency In Hertz
50.0 single location or 60.0 single location -
Thread Series Designator
Un -
Terminal Type And Quantity
2 tab, solder lug
More from these suppliers
- 5925-00-311-2330 MPN APL111-1-41-153-MCircuit Breaker
- 5925-00-420-8348 MPN APL5-292-2Circuit Breaker
- 5925-01-024-1022 MPN APL1-124-6Circuit Breaker
- 5925-01-024-9568 MPN UPL13327-217Circuit Breaker
- 5925-01-131-0200 MPN APGN66-1REC3-7026-3Circuit Breaker
- 5925-01-160-7607 MPN AAP-12-1-65F-502Circuit Breaker
- 5925-01-160-7609 MPN AP112-8475-1Circuit Breaker
- 5925-01-173-2837 MPN APL-111-1REC2-42F-752-MACircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-283-2930 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
T11-2-3.00A-02-20A | Sensata Technologies Maryland, Inc |