NSN 5925-01-286-6590
Overload Switch
Single pole type body style, plastic case material, 1 poles, thready qty per inch (tpi): 32.
Manufacturer part number 219-1-1-63F-5-8-20 for national stock number 5925012866590.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-286-6590.
-
MPN or Model
219-1-1-63F-5-8-20
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
Between 5.110 inches and 5.140 inches -
Body Width
Between 1.016 inches and 1.036 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 3.535 inches and 3.565 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.735 inches and 2.765 inches -
Boss Height
Between 0.205 inches and 0.235 inches -
Mounting Surface To Terminal End Distance
Between 3.535 inches and 3.565 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 threaded hole -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 200 pct single location and 130.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant and shock resistant and vibration resistant -
Frequency In Hertz
50.0 single location or 60.0 single location -
Unpackaged Unit Weight
9.000 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5930-01-519-8209 MPN C53GAB140E-0335Thermostatic Switch
- 5925-00-182-7452 MPN APL-1-1-51-503-MCircuit Breaker
- 5925-00-307-4014 MPN APL1-55629-1-033Circuit Breaker
- 5925-00-367-7620 MPN UPL-1-1-62-203Circuit Breaker
- 5925-00-429-1717 MPN APL1-1R0-55629-2-026Circuit Breaker
- 5925-00-433-8594 MPN APL-1-1-103-39Circuit Breaker
- 5925-00-522-2532 MPN APL-1-1911-1Circuit Breaker
- 5925-01-018-4254 MPN APL-11-55629-3-023Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-286-6590 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
219-1-1-63F-5-8-20 | Sensata Technologies Maryland, Inc |
219-1-1-63F-6-8-20 | Sensata Technologies Maryland, Inc |
Stock Check