NSN 5925-01-293-9931
Overload Switch
Metal case material, at 3 oclock and at 9 oclock nonturn device location, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number M39019/06-330 for national stock number 5925012939931.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-293-9931.
-
MPN or Model
M39019/06-330
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Bushing Length
Between 0.349 inches and 0.411 inches -
Body Length
1.562 inches -
Body Width
1.937 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.906 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.594 inches and 0.656 inches -
Nonturn Device Location
At 3 oclock and at 9 oclock -
Nonturn Device Radius
Between 0.594 inches and 0.656 inches -
Nonturn Device Length
Between 0.099 inches and 0.161 inches -
Nonturn Device Diameter
Between 0.219 inches and 0.281 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.828 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Features Provided
High inrush protection -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
9.0 amperes ac all locations and 9.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 50.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 at 200 pct all locations and 0.950 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Hermetically sealed -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc -
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc -
Frequency In Hertz
400.0 all locations -
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unef -
Terminal Type And Quantity
6 wire hook -
Specification Data
81349-mil-c-39019/6 government specification
More from these suppliers
- 5905-00-006-6908 MPN RNC60H1181FRFilm Fixed Resistor
- 5905-00-006-6986 MPN RNR60K5491FSFilm Fixed Resistor
- 5905-00-009-8037 MPN RNC65K8063FSFilm Fixed Resistor
- 5935-00-018-0481 MPN MIL-C-26482Electrical Plug Connector
- 5905-00-020-2400 MPN RV2NAYSD101BNonprecision Nonwire Wound Variable Resistor
- 5935-00-028-0950 MPN M28748/10G0X01AElectrical Receptacle Connector
- 5905-00-031-3902 MPN MIL-R-55182/6Film Fixed Resistor
- 5905-00-035-4340 MPN RWR89S3400FRInductive Wire Wound Fixed Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-293-9931 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M39019/06-330 | Military Specifications |
MIL-PRF-39019/6G | Military Specifications |
MIL-C-39019/6 | Military Specifications |