1-321-802-5889

NSN 5925-01-294-3076

Overload Switch

About this product

Rectangular dimensional envelope body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.

Manufacturer part number 11024337 for national stock number 5925012943076.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-01-294-3076.

  • MPN or Model

    11024337

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    0.1 lb
  • Body Style
    Rectangular dimensional envelope
  • Overall Length
    1.810 inches
  • Overall Height
    0.570 inches
  • Overall Width
    1.140 inches
  • Case Material
    Plastic
  • Fragility Factor
    Moderately rugged
  • Pole Quantity
    1
  • Arc Quenching Method
    Magnetic blowout
  • Mounting Facility Type And Quantity
    1 threaded bushing
  • Storage Type
    General purpose warehouse
  • Thready Qty Per Inch (tpi)
    27
  • Maximum Continuous Load Current Rating Per Pole
    200.0 milliamperes ac single location and 200.0 milliamperes dc single location
  • Operating Voltage Type And Rating Per Pole In Volts
    250.0 ac single location and 28.0 dc single location
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    200.0 ac single location
  • Circuit Protection Type
    Overcurrent single location
  • Trip Release Method
    Thermal single location
  • Trip Release Characteristic
    Time delay single location
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    140.0 single location
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 push button
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole one
  • Internal Trip Release Configuration
    Series trip single location
  • Thread Size
    0.375 inches
  • Trip Delay Time In Seconds Per Rated Continuous Current
    10.000 at 200 pct single location and 40.000 at 200 pct single location
  • Inclosure Protection Type For Which Designed
    Dustproof
  • Trip Release Ambient Tempurature Rating
    40.0 degrees celsius single location
  • Frequency In Hertz
    60.0 single location
  • Thread Series Designator
    Uns
  • Terminal Type And Quantity
    2 quick disconnect, male
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-01-294-3076 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925012943076

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
11024337 Us Army Armament Research
2-5700-IG1-P10-0.2A Oakland Industries Ltd
PR11-2-0.20-A-XX-10 Sensata Technologies Maryland, Inc
45-700-P10-0.20A Oakland Industries Ltd
Stock Check