NSN 5925-01-299-3571
Overload Switch
Includes 2 shunt release devices.
Manufacturer part number 3WE5311-3AB42-ZF60 for national stock number 5925012993571.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-299-3571.
-
MPN or Model
3WE5311-3AB42-ZF60
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Rectangular dimensional envelope -
Overall Length
529.0 millimeters -
Overall Height
339.0 millimeters -
Overall Width
358.0 millimeters -
Case Material
Plastic -
Unthreaded Mounting Hole Diameter
12.5 millimeters -
Switch Contact Arrangement
Single pole, double throw -
Pole Quantity
3 -
Arc Quenching Method
Air -
Mounting Facility Type And Quantity
4 unthreaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
1600.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
50000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 push button -
Actuator Function
Trip w/separate reset -
Auxiliary Switch Function And Quantity
2 control -
Inclosure Protection Type For Which Designed
General purpose -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Unpackaged Unit Weight
59.1 kilograms -
Terminal Type And Quantity
6 tab, solder lug
More from these suppliers
- 5950-01-303-2691 MPN 4NC1331-0CE20Current Transformer
- 5925-01-596-7069 MPN 5SP4380-7Circuit Breaker
- 6110-01-301-0746 MPN 3TB4210-0AN1Magnetic Contactor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-299-3571 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
3WE5311-3AB42-ZF60 | Siemens Energy & Automation Inc. |
3WE5311-3AB42-ZF60 | Siemans Energy And Automation Inc |