NSN 5925-01-303-4565
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 2.
Manufacturer part number M555629/9-044 for national stock number 5925013034565.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-303-4565.
-
MPN or Model
M555629/9-044
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Thread Pitch Diameters
+0.1177/+0.1214 inches -
Body Style
Multipole-multiple actuator type -
Body Length
2.000 inches -
Body Width
1.500 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.560 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.130 inches -
Mounting Surface To Terminal End Distance
2.032 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.130 at 200 pct all locations and 1.400 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and vibration resistant and moisture resistant and shock resistant and salt spray proof -
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 tab, solder lug -
Specification Data
81349-mil-c-55629/19 government specification
More from these suppliers
- 5905-00-001-3031 MPN RCR42G183KSComposition Fixed Resistor
- 5905-00-004-6109 MPN RNR55C1400FSFilm Fixed Resistor
- 5905-00-004-7686 MPN RNC60J2261BSFilm Fixed Resistor
- 5935-00-005-2847 MPN MILC83723-75Electrical Plug Connector
- 5905-00-006-6939 MPN RN60E1273BFilm Fixed Resistor
- 5905-00-007-0734 MPN RE70N1211Noninductive Wire Wound Fixed Resistor
- 5905-00-007-7238 MPN MIL-R-39005/1Noninductive Wire Wound Fixed Resistor
- 5905-00-011-7109 MPN RV6TAYSA502BNonprecision Nonwire Wound Variable Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-303-4565 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M555629/9-044 | Military Specifications |
MIL-C-55629/9 | Military Specifications |