NSN 5925-01-304-0370
Overload Switch
Single pole type body style, metal case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number AP-7-1R-52-1752 for national stock number 5925013040370.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-304-0370.
-
MPN or Model
AP-7-1R-52-1752
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Single pole type -
Bushing Length
0.380 inches -
Body Length
1.500 inches -
Body Width
0.625 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.875 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.605 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
17.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.375 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.850 at 200 pct single location and 4.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Hermetically sealed -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc -
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc -
Thread Series Designator
Unef -
Terminal Type And Quantity
2 tab w/screw
More from these suppliers
- 5925-00-814-2187 MPN APL111-1CRCircuit Breaker
- 5925-00-829-2456 MPN AP112-1-4-1-152Circuit Breaker
- 5925-01-100-4029 MPN APG-6666-1-62-303Circuit Breaker
- 5925-01-132-8567 MPN G330168-1Circuit Breaker
- 5925-01-226-9953 MPN UPL1-1-61-203MCircuit Breaker
- 5925-01-238-4038 MPN AP-12-7895-10Circuit Breaker
- 5925-01-283-2930 MPN T11-2-3.00A-02-20ACircuit Breaker
- 5925-01-400-0813 MPN AP-17-1R-79-153Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-304-0370 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AP-7-1R-52-1752 | Sensata Technologies Maryland, Inc |