NSN 5925-01-308-3469
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number MPL-1-1-66-153-M for national stock number 5925013083469.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-308-3469.
-
MPN or Model
MPL-1-1-66-153-M
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.3 lb -
Body Style
Single pole type -
Body Length
Between 2.480 inches and 2.500 inches -
Body Width
Between 0.735 inches and 0.765 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.925 inches and 1.955 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.135 inches and 0.181 inches -
Mounting Surface To Terminal End Distance
Between 2.594 inches and 2.656 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 200 pct single location and 100.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus proof -
Frequency In Hertz
50.0 single location or 60.0 single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5930-01-129-7668 MPN 5004-021-129Thermostatic Switch
- 5930-01-580-7712 MPN AP17-1-52-252Toggle Switch
- 5925-00-044-5793 MPN AP111-165-12Circuit Breaker
- 5925-00-443-9244 MPN APL-111-1R0-42-502-MCircuit Breaker
- 5925-00-450-5190 MPN APL11-1177-2Circuit Breaker
- 5925-00-790-4903 MPN AP-1-4-51-502Circuit Breaker
- 5925-00-952-5586 MPN 501B152Circuit Breaker
- 5925-01-012-6209 MPN UPL-1-1REC2-66-163Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-308-3469 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
MPL-1-1-66-153-M | Sensata Technologies Maryland, Inc |
Stock Check
![](/public/images/partscage_shelf3.png)