NSN 5925-01-309-8584
Overload Switch
Single pole type body style, plastic case material, 1 poles, arc quenching method: magnetic blowout.
Manufacturer part number AM1-B3-A-45-3 for national stock number 5925013098584.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-309-8584.
-
MPN or Model
AM1-B3-A-45-3
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
Between 2.480 inches and 2.500 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.925 inches and 1.955 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches -
Boss Height
Between 0.135 inches and 0.165 inches -
Mounting Surface To Terminal End Distance
2.656 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
45.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct single location and 1.700 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and humidity resistant and moisture resistant and shock resistant and vibration resistant -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5925-00-229-7666 MPN CD3-A3-15-480-60-9Circuit Breaker
- 5925-00-434-2038 MPN AM12-2-250-400-1Circuit Breaker
- 5925-00-501-7677 MPN AM1510MG3-15-115-60HZ-1Circuit Breaker
- 5925-00-522-2532 MPN AM1Z10-1Circuit Breaker
- 5925-00-578-4774 MPN AM13MG3-5-28VDCCURVE5Circuit Breaker
- 5925-00-595-9394 MPN AM33MG6-30-250-4-60Circuit Breaker
- 5925-00-967-6199 MPN HE1-B3-3-50VDC-PCircuit Breaker
- 5925-01-020-9501 MPN AM333MG6-15-115V-400CPS,CURVE15Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-309-8584 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM1-B3-A-45-3 | Eaton Corp |
UPL-1-1-51-453 | Sensata Technologies Maryland, Inc |