NSN 5925-01-310-3667
Overload Switch
Multipole-single actuator type body style, 2 poles, 32 thready qty per inch (tpi), maximum continuous load current rating per pole: 5.0 amperes ac single location.
Manufacturer part number 295-11-1-62F-3-502-AM for national stock number 5925013103667.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-310-3667.
-
MPN or Model
295-11-1-62F-3-502-AM
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Multipole-single actuator type -
Body Length
2.490 inches -
Body Width
0.750 inches -
Center To Center Distance Between Terminals Parallel To Length
2.060 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.150 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
2 threaded hole -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location -
Circuit Protection Type
Overvoltage single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Reset Method
Electric -
Main Contact Tripping Mechanism Type
Trip free -
Actuator Function
Trip-reset -
Internal Trip Release Configuration
Series trip single location -
Frequency In Hertz
50.0 single location or 60.0 single location -
Thread Series Designator
Iso m -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5945-00-966-8459 MPN 307-105Electronic Chopper
- 5925-00-058-4153 MPN AP-12-4-51-151Circuit Breaker
- 5925-00-479-7902 MPN APL-11-1-42-752-MCircuit Breaker
- 5925-01-044-0307 MPN AP-112-1-7-2-202Circuit Breaker
- 5925-01-108-4246 MPN AP-112-1-40-602Circuit Breaker
- 5925-01-160-9068 MPN UPL-111-7007-47Circuit Breaker
- 5925-01-255-2442 MPN AP-116-1-65-103Circuit Breaker
- 5925-01-320-6905 MPN APL11-1709-380Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-310-3667 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
295-11-1-62F-3-502-AM | Sensata Technologies Maryland, Inc |
295-11-1-62F-3-502-AM | Sensata Technologies Maryland, Inc |
295-11-1-62F-3-502-AM | Sensata Technologies Maryland, Inc |
295-11-1-62F-3-502-AM | Sensata Technologies Maryland, Inc |
Stock Check
![](/public/images/partscage_shelf3.png)