NSN 5925-01-311-3079
Overload Switch
Rectangular dimensional envelope body style, plastic case material, moderately rugged fragility factor, pole quantity: 2.
Manufacturer part number BQ2-C050 for national stock number 5925013113079.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-311-3079.
-
MPN or Model
BQ2-C050
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Rectangular dimensional envelope -
Overall Length
3.060 inches -
Overall Height
2.000 inches -
Overall Width
2.960 inches -
Case Material
Plastic -
Fragility Factor
Moderately rugged -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 terminal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Inclosure Protection Type For Which Designed
General purpose -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
2 clip and 2 tab w/screw
More from these suppliers
- 6110-01-202-4698 MPN DA83-01-069-17Motor Starter
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-311-3079 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
BQ2-C050 | Challenger Electrical Equipment Corp |