NSN 5925-01-317-1825
Overload Switch
Metal case material, moderately rugged fragility factor, 1 poles, arc quenching method: magnetic blowout.
Manufacturer part number APGN-6-1-53-203 for national stock number 5925013171825.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-317-1825.
-
MPN or Model
APGN-6-1-53-203
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Thread Pitch Diameters
+0.4752/+0.4787 inches -
Bushing Length
0.625 inches -
Body Length
2.000 inches -
Body Width
0.750 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
Nonturn Device Radius
0.656 inches -
Nonturn Device Length
0.130 inches -
Nonturn Device Diameter
Between 0.151 inches and 0.161 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
2.232 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.500 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 at 200 pct single location and 150.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Moisture resistant and salt spray proof and shock resistant and vibration resistant -
Unpackaged Unit Weight
3.000 ounces -
Thread Series Designator
Un -
Terminal Type And Quantity
2 tab w/screw
More from these suppliers
- 5925-00-226-1155 MPN 501I102Circuit Breaker
- 5925-00-234-0122 MPN RRP401-880-2Circuit Breaker
- 5925-00-448-9786 MPN AP-1-1-41-251Circuit Breaker
- 5925-00-597-1267 MPN APL-111-1R0-55629/6-032Circuit Breaker
- 5925-01-025-7007 MPN AP112-1-4-1-402Circuit Breaker
- 5925-01-037-6891 MPN AP1-1R4-2-501Circuit Breaker
- 5925-01-047-2140 MPN AP1-020-211-0228Circuit Breaker
- 5925-01-088-0653 MPN UPG11-1434-02Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-317-1825 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APGN-6-1-53-203 | Sensata Technologies Maryland, Inc |