NSN 5925-01-317-9323
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number CD3-C3-A-50-240-3 for national stock number 5925013179323.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-317-9323.
-
MPN or Model
CD3-C3-A-50-240-3
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
Between 5.790 inches and 5.810 inches -
Body Width
3.108 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 3.537 inches and 3.557 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 1.016 inches and 1.036 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.740 inches and 2.760 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 1.016 inches and 1.036 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.209 inches and 0.229 inches -
Mounting Surface To Terminal End Distance
Between 2.599 inches and 2.619 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.280 at 200 pct all locations and 1.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Dustproof and fungus resistant -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5925-00-081-7593 MPN 3XAM17-44-208-400-55Circuit Breaker
- 5925-00-450-5191 MPN 72-251-3MG6Circuit Breaker
- 5925-00-487-7542 MPN CD3C3-2A440AC400HZ2Circuit Breaker
- 5925-00-497-4293 MPN AM333-5-240-400-16Circuit Breaker
- 5925-00-842-4970 MPN AM333MG6-20-240VAC400C16Circuit Breaker
- 5925-00-850-0440 MPN AM17-2-32VDC55Circuit Breaker
- 5925-01-023-2475 MPN AM1-A3-30-2Circuit Breaker
- 5925-01-101-6068 MPN GB3-G3-M-15-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-317-9323 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
CD3-C3-A-50-240-3 | Eaton Corp |