NSN 5925-01-317-9963
Overload Switch
Multipole-single actuator type body style, plastic case material, at 12 oclock and at 3 oclock and at 9 oclock nonturn device location, switch contact arrangement: single pole, double throw.
Manufacturer part number APGN-111-1REC4-65F-252 for national stock number 5925013179963.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-317-9963.
-
MPN or Model
APGN-111-1REC4-65F-252
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Thread Pitch Diameters
+0.4752/+0.4787 inches -
Body Style
Multipole-single actuator type -
Bushing Length
0.625 inches -
Body Length
2.000 inches -
Body Width
2.250 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Nonturn Device Location
At 12 oclock and at 3 oclock and at 9 oclock -
Nonturn Device Radius
0.656 inches -
Nonturn Device Length
0.130 inches -
Nonturn Device Diameter
Between 0.151 inches and 0.161 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
2.200 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
2.5 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.500 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
7.000 at 125 pct all locations and 90.000 at 125 pct all locations and 3.000 at 150 pct all locations and 40.000 at 150 pct all locations and 1.000 at 200 pct all locations and 12.000 at 200 pct all locations and 0.200 at 400 pct all locations and 3.000 at 400 pct all locations and 0.080 at 600 pct all locations and 1.000 at 600 pct all locations and 0.030 at 800 pct all locations and 0.700 at 800 pct all locations and 0.016 at 1000 pct all locations and 0.300 at 1000 pct all locations -
Inclosure Protection Type For Which Designed
Hermetically sealed and shock resistant and vibration resistant -
Switch Terminal Type
Quick disconnect, male -
Switch Current Rating And Type In Amps
10.0 ac and 5.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Unpackaged Unit Weight
9.000 ounces -
Thread Series Designator
Un -
Terminal Type And Quantity
4 quick disconnect, male
More from these suppliers
- 5925-00-257-9043 MPN AP112-1R4-2-153Circuit Breaker
- 5925-00-902-2786 MPN 720B202Circuit Breaker
- 5925-01-037-6891 MPN AP1-1R4-2-501Circuit Breaker
- 5925-01-039-3764 MPN AP-MIL-112-1-7-2-1252Circuit Breaker
- 5925-01-104-7351 MPN AP-1-1-51-102Circuit Breaker
- 5925-01-108-3571 MPN AP-1-1-50-502Circuit Breaker
- 5925-01-112-4403 MPN 205-11-1REC3-52F-2-502-A-M-OCircuit Breaker
- 5925-01-134-8470 MPN APG111-1REC3-66-752-01Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-317-9963 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APGN-111-1REC4-65F-252 | Sensata Technologies Maryland, Inc |