NSN 5925-01-317-9965

Overload Switch

About this product

Multipole-single actuator type body style, plastic case material, at 3 oclock and at 9 oclock nonturn device location, switch contact arrangement: single pole, double throw.

Manufacturer part number APGN-11-1REC4-65-102 for national stock number 5925013179965.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-01-317-9965.

  • MPN or Model

    APGN-11-1REC4-65-102

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • Thread Pitch Diameters
    +0.4752/+0.4787 inches
  • Body Style
    Multipole-single actuator type
  • Bushing Length
    0.625 inches
  • Body Length
    2.000 inches
  • Body Width
    1.500 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    1.530 inches
  • Center To Center Distance Between Terminals Parallel To Width
    0.750 inches
  • Nonturn Device Location
    At 3 oclock and at 9 oclock
  • Nonturn Device Radius
    0.656 inches
  • Nonturn Device Length
    0.130 inches
  • Nonturn Device Diameter
    Between 0.151 inches and 0.161 inches
  • Switch Contact Arrangement
    Single pole, double throw
  • Fragility Factor
    Moderately rugged
  • Mounting Surface To Terminal End Distance
    2.200 inches
  • Pole Quantity
    2
  • Arc Quenching Method
    Magnetic blowout
  • Mounting Facility Type And Quantity
    1 threaded bushing w/panel seal
  • Storage Type
    General purpose warehouse
  • Special Handling Feature
    Magnetic
  • Thready Qty Per Inch (tpi)
    32
  • Maximum Continuous Load Current Rating Per Pole
    1.0 amperes ac all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    250.0 ac all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    3500.0 ac all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Magnetic-hydraulic all locations
  • Trip Release Characteristic
    Time delay all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    115.0 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole two
  • Auxiliary Switch Function And Quantity
    1 alarm
  • Internal Trip Release Configuration
    Series trip all locations
  • Thread Size
    0.500 inches
  • Switch Location And Position Designation
    Internal at pole one
  • Trip Delay Time In Seconds Per Rated Continuous Current
    7.000 at 125 pct all locations and 90.000 at 125 pct all locations and 3.000 at 150 pct all locations and 40.000 at 150 pct all locations and 1.000 at 200 pct all locations and 12.000 at 200 pct all locations and 0.200 at 400 pct all locations and 3.000 at 400 pct all locations and 0.080 at 600 pct all locations and 1.000 at 600 pct all locations and 0.030 at 800 pct all locations and 0.700 at 800 pct all locations and 0.016 at 1000 pct all locations and 0.300 at 1000 pct all locations
  • Inclosure Protection Type For Which Designed
    Hermetically sealed and shock resistant and vibration resistant
  • Switch Terminal Type
    Quick disconnect, male
  • Switch Current Rating And Type In Amps
    10.0 ac and 5.0 dc
  • Switch Voltage Rating And Type In Volts
    250.0 ac and 30.0 dc
  • Frequency In Hertz
    50.0 all locations or 60.0 all locations
  • Unpackaged Unit Weight
    6.000 ounces
  • Thread Series Designator
    Un
  • Terminal Type And Quantity
    4 quick disconnect, male
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-01-317-9965 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925013179965

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
APGN-11-1REC4-65-102 Sensata Technologies Maryland, Inc
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.