NSN 5925-01-319-0410
Overload Switch
Rectangular dimensional envelope body style, metal case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number 30056-8 for national stock number 5925013190410.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-319-0410.
-
MPN or Model
30056-8
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.3 lb -
Body Style
Rectangular dimensional envelope -
Overall Length
Between 1.318 inches and 1.338 inches -
Overall Height
Between 1.083 inches and 1.103 inches -
Overall Width
Between 1.240 inches and 1.260 inches -
Case Material
Metal -
Fragility Factor
Moderately rugged -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 terminal -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
8.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
24.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Instantaneous single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Automatic -
Internal Trip Release Configuration
Series trip single location -
Inclosure Protection Type For Which Designed
Hermetically sealed -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Terminal Type And Quantity
2 threaded stud
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-319-0410 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
30056-8 | Cole Hersee Company |
812008 | Littelfuse, Inc. |