NSN 5925-01-330-3976
Overload Switch
Multipole-multiple actuator type body style, plastic case material, 2 poles, maximum continuous load current rating per pole: 15.0 amperes ac all locations.
Manufacturer part number AM2S-A38A39-LA-07-D-A-52-15-252 for national stock number 5925013303976.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-330-3976.
-
MPN or Model
AM2S-A38A39-LA-07-D-A-52-15-252
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Multipole-multiple actuator type -
Body Length
2.500 inches -
Body Width
1.500 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Boss Height
0.150 inches -
Mounting Surface To Terminal End Distance
2.471 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 threaded hole -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.500 at 200 pct all locations and 5.250 at 200 pct all locations -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud
More from these suppliers
- 5925-00-103-6378 MPN AM333MG6L1-25-50UDC5CR4-250VAC4Circuit Breaker
- 5925-00-107-4230 MPN AM12-7-250-60-4Circuit Breaker
- 5925-00-185-4020 MPN AM333-20-125-4-60Circuit Breaker
- 5925-00-272-8898 MPN AM333-30-208-4-60Circuit Breaker
- 5925-00-622-0354 MPN JL1A2-4-3Circuit Breaker
- 5925-00-814-4088 MPN AM12MG6-2-250VAC400C16Circuit Breaker
- 5925-00-905-9797 MPN AM1516MG3-2.5-250VAC3-400HZCircuit Breaker
- 5925-00-984-6125 MPN 53-119MG3-5-416V-AC-400C3Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-330-3976 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM2S-A38A39-LA-07-D-A-52-15-252 | Eaton Corp |