NSN 5925-01-330-5275
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number 2612325-2 for national stock number 5925013305275.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-330-5275.
-
MPN or Model
2612325-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
2.4 lb -
Body Style
Multipole-multiple actuator type -
Body Length
Between 5.115 inches and 5.135 inches -
Body Width
3.108 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 3.540 inches and 3.560 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 1.016 inches and 1.036 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.740 inches and 2.760 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 1.016 inches and 1.036 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.210 inches and 0.230 inches -
Mounting Surface To Terminal End Distance
Between 3.540 inches and 3.560 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
80.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 18.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Humidity resistant and shock resistant and vibration resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
10.0 ac and 3.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 4920-00-219-1371 MPN 10128-1Spherical Adapter
- 5950-00-646-1799 MPN 845090Radio Frequency Coil
- 5905-00-968-3749 MPN A01118-814Film Fixed Resistor
- 5905-01-317-3018 MPN 2613333-5Inductive Wire Wound Fixed Resistor
- 5930-01-294-1454 MPN APL-0-IRSToggle Switch
- 5925-00-407-2192 MPN APL1R1195-17Circuit Breaker
- 5925-01-024-9568 MPN APL-1-1-62-302-MCircuit Breaker
- 5925-01-044-0307 MPN AP-112-1-7-2-202Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-330-5275 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
2612325-2 | Alliant Techsystems Operations Llc |
229-3-21246-2 | Sensata Technologies Maryland, Inc |