NSN 5925-01-331-4062
Overload Switch
Multipole-single actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number APGN-662-22005-7 for national stock number 5925013314062.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-331-4062.
-
MPN or Model
APGN-662-22005-7
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.3 lb -
Body Style
Multipole-single actuator type -
Bushing Length
Between 0.610 inches and 0.640 inches -
Body Length
Between 1.985 inches and 2.015 inches -
Body Width
Between 2.235 inches and 2.265 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.615 inches and 1.645 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.735 inches and 0.765 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
2.282 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Auxiliary Trip Coil Voltage Type And Rating In Volts
115.0 ac third location -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series/relay trip third location -
Thread Size
0.500 inches -
Trip Release Duty Cycle
Continuous third location -
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct all locations and 1.900 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Dustproof and fungus proof -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Uns -
Terminal Type And Quantity
8 tab, solder lug
More from these suppliers
- 5925-00-159-7622 MPN AP444-253-4Circuit Breaker
- 5925-00-311-2327 MPN APL11-1R0-55629-4-101Circuit Breaker
- 5925-01-076-3653 MPN APL-15-3730-2Circuit Breaker
- 5925-01-114-9819 MPN UPGH111-1REC2-2630-9Circuit Breaker
- 5925-01-138-4058 MPN 219-3-1-66-5-8-50Circuit Breaker
- 5925-01-145-5328 MPN APL113-8918-2Circuit Breaker
- 5925-01-156-7724 MPN G330169-9Circuit Breaker
- 5925-01-158-4512 MPN IUGN11-1-53-5.00Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-331-4062 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APGN-662-22005-7 | Sensata Technologies Maryland, Inc |