NSN 5925-01-342-8902
Overload Switch
Multipole-single actuator type body style, metal case material, at 3 oclock and at 9 oclock nonturn device location, fragility factor: moderately rugged.
Manufacturer part number AP17-1-52-103 for national stock number 5925013428902.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-342-8902.
-
MPN or Model
AP17-1-52-103
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.5 lb -
Body Style
Multipole-single actuator type -
Bushing Length
0.380 inches -
Body Length
1.562 inches -
Body Width
1.281 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.875 inches -
Center To Center Distance Between Terminals Parallel To Width
0.625 inches -
Nonturn Device Location
At 3 oclock and at 9 oclock -
Nonturn Device Radius
0.625 inches -
Nonturn Device Length
0.130 inches -
Nonturn Device Diameter
0.147 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.780 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
Between pole one and two -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 at 200 pct single location and 6.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Hermetically sealed -
Thread Series Designator
Unef -
Terminal Type And Quantity
4 wire hook
More from these suppliers
- 4820-00-383-5455 MPN 568-8700-938382PC5Fluid Valve Stem
- 4820-00-469-0201 MPN 404-2409-69957ALT17PCD3Plug Cock
- 5905-00-843-1201 MPN 2106224-3Inductive Wire Wound Fixed Resistor
- 5935-01-067-9458 MPN 3155830-713Electrical Receptacle Connector Body
- 4820-01-077-7208 MPN 3295209PC557Safety Relief Valve
- 4820-01-128-3873 MPN 820-4551728-44Needle Valve Stem
- 4820-01-153-1508 MPN 803-5001004-A12X-36Valve Tailpiece
- 5930-01-166-7326 MPN 5189178-008Push Switch
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-342-8902 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AP17-1-52-103 | Sensata Technologies Maryland, Inc |
5104735-8 | Naval Sea Systems Command |