NSN 5925-01-344-8927
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number 5906899-2 for national stock number 5925013448927.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-344-8927.
-
MPN or Model
5906899-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Bushing Length
0.250 inches -
Body Length
0.781 inches -
Body Width
0.593 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
0.500 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.343 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac single location and 2.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 28.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2800.0 ac single location and 6000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.438 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
1.500 at 200 pct single location and 40.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Frequency In Hertz
400.0 single location -
Unpackaged Unit Weight
25.0 grams -
Thread Series Designator
Uns -
Terminal Type And Quantity
2 tab w/screw
More from these suppliers
- 5925-00-731-7709 MPN MP-934-GCircuit Breaker
- 5925-01-207-0859 MPN MP-700-092-10Circuit Breaker
- 5930-00-007-7760 MPN A3-1112-01Toggle Switch
- 5945-00-062-6908 MPN 6042H93Electromagnetic Relay
- 5950-00-229-6276 MPN 3600ITEM146Electrical Coil
- 5930-00-557-5175 MPN 8775K15Toggle Switch
- 5930-00-615-6091 MPN 8946K8Toggle Switch
- 5950-00-648-4065 MPN 999-1-24X1ALT2ITEM8DElectrical Coil
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-344-8927 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
5906899-2 | Hamilton Sundstrand Corporation |
4310-051-2 | Labinal, Llc |
4310-051-2 | Labinal, Llc |