NSN 5925-01-345-0156
Overload Switch
Multipole-single actuator type body style, metal case material, at 12 oclock nonturn device location, fragility factor: moderately rugged.
Manufacturer part number AP17-1-61-201 for national stock number 5925013450156.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-345-0156.
-
MPN or Model
AP17-1-61-201
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Thread Pitch Diameters
+0.3503/+0.3537 inches -
Body Style
Multipole-single actuator type -
Bushing Length
0.380 inches -
Body Length
1.562 inches -
Body Width
1.281 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.875 inches -
Center To Center Distance Between Terminals Parallel To Width
0.625 inches -
Nonturn Device Location
At 12 oclock -
Nonturn Device Radius
0.625 inches -
Nonturn Device Diameter
0.250 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.950 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
0.2 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
Between pole one and two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.070 at 200 pct all locations and 0.700 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant and hermetically sealed -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Unpackaged Unit Weight
3.600 ounces -
Thread Series Designator
Unef -
Terminal Type And Quantity
4 screw
More from these suppliers
- 5925-00-161-9167 MPN APL1-515-18Circuit Breaker
- 5925-00-200-9310 MPN APL-1-1-61-303-MCircuit Breaker
- 5925-00-238-0412 MPN 295-111-1RE-2343-4Circuit Breaker
- 5925-00-964-4989 MPN 712A401Circuit Breaker
- 5925-01-022-5093 MPN UPG1-1-62-302-90Circuit Breaker
- 5925-01-039-4098 MPN AP-MIL-1-1-7-2-203Circuit Breaker
- 5925-01-044-9168 MPN 203-2-1-61-502Circuit Breaker
- 5925-01-046-0614 MPN APL11-55629-5-066Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-345-0156 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AP17-1-61-201 | Sensata Technologies Maryland, Inc |