NSN 5925-01-346-7827
Overload Switch
Line and load lugs included.
Manufacturer part number HFD3090L for national stock number 5925013467827.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-346-7827.
-
MPN or Model
HFD3090L
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
4.7 lb -
Body Style
Rectangular dimensional envelope -
Overall Length
6.000 inches -
Overall Height
3.375 inches -
Overall Width
4.125 inches -
Case Material
Plastic -
Unthreaded Mounting Hole Diameter
0.196 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
90.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
25000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
6 compression
More from these suppliers
- 5950-00-564-2852 MPN 422D295G01Current Transformer
- 5930-01-360-6168 MPN E22PB1CPush Switch
- 5930-01-360-6168 MPN PB4AALABPush Switch
- 5925-00-018-6646 MPN HQP3035HCircuit Breaker
- 5925-00-103-1736 MPN S1400241Circuit Breaker
- 5925-00-896-4263 MPN QCL1030Circuit Breaker
- 5925-00-917-3667 MPN 451D860G03Circuit Breaker
- 5925-01-039-6651 MPN FD3125Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-346-7827 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
HFD3090L | Eaton Corporation |