NSN 5925-01-347-9838
Overload Switch
Single pole type body style, 1 poles, 5.0 amperes dc single location maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 50.0 dc single location.
Manufacturer part number MIL-C-55629/20 for national stock number 5925013479838.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-347-9838.
-
MPN or Model
MIL-C-55629/20
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Bushing Length
Between 0.115 inches and 0.145 inches -
Body Length
Between 1.969 inches and 2.031 inches -
Body Width
Between 0.735 inches and 0.765 inches -
Center To Center Distance Between Terminals Parallel To Length
Between 1.499 inches and 1.561 inches -
End Application
B-1 -
Mounting Surface To Terminal End Distance
2.232 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
6 terminal -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Instantaneous single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location -
Reset Method
Manual -
Terminal Type And Quantity
8 screw
More from these suppliers
- 5905-00-003-8280 MPN MILR39017-1EFilm Fixed Resistor
- 5905-00-004-6083 MPN MIL-R-55182/3Film Fixed Resistor
- 5935-00-004-6257 MPN M39012/16-0014Electrical Plug Connector
- 5905-00-005-2894 MPN RNC65K6810FSFilm Fixed Resistor
- 5930-00-005-7051 MPN M8805/77-001Sensitive Switch
- 5935-00-005-8862 MPN M83723/21R1303WElectrical Receptacle Connector
- 5905-00-005-8931 MPN RN50C3651FFilm Fixed Resistor
- 5905-00-006-5556 MPN MIL-R-39005/4Noninductive Wire Wound Fixed Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-347-9838 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
MIL-C-55629/20 | Military Specifications |
M55629/20LR | Military Specifications |
MIL-PRF-55629/20 | Military Specifications |