NSN 5925-01-349-6779
Overload Switch
Plastic case material, moderately rugged fragility factor, 3 poles, storage type: general purpose warehouse.
Manufacturer part number 302-11-105 for national stock number 5925013496779.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-349-6779.
-
MPN or Model
302-11-105
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Case Material
Plastic -
Fragility Factor
Moderately rugged -
Pole Quantity
3 -
Storage Type
General purpose warehouse -
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Internal Trip Release Configuration
Series trip all locations -
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 200 pct all locations and 32.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant -
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations
More from these suppliers
- 5930-00-256-0698 MPN 319-03-520Rotary Switch
- 5930-01-005-6478 MPN 700653-01Rotary Switch
- 5930-01-139-1453 MPN 11444-101Rotary Switch
- 5930-01-209-4479 MPN 1592-01Rotary Switch
- 5930-01-519-7871 MPN PL708677 REV H, ITEM 190Rotary Switch
- 5925-01-226-4961 MPN 706381 PIECE 69Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-349-6779 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
302-11-105 | L-3 Communications Westwood |